| TYPE |
Transformer Turns Ratio Tester |
| PHYSICAL SPECIFICATIONS |
Dimensions: 12” x 10” x 8” (30.4 cm x 25.4 cm x 20.3 cm)
Weight: 9 lbs. (4.3 Kg) |
| INPUT POWER |
90 to 240 Vac, 50/60 Hz
SLA battery delivering up to 4 hours of continuous operation per charge |
| MEASURING METHOD |
|
| RATIO MEASURING RANGE |
0.8 - 15,000 (5 digit resolution) |
| TURNS-RATIO ACCURACY |
40 Vac: 0.8-1,999 (0.1%), 2,000-3,999 (0.25%), 4,000-15,000 (1%)
4 Vac: 0.8-1,999 (0.1%), 2,000-3,999 (0.25%), 4,000-15,000 (2%) |
| TEST VOLTAGE |
4 Vac @ 500mA, 40 Vac @ 70mA |
| PHASE ANGLE MEASUREMENT |
0 - 360 degrees, Accuracy ±0.2 degree (±1 digit) |
| POLARITY READING |
In-Phase or Out-of-Phase indication |
| EXCITATION CURRENT READING RANGE |
0-2 Amperes, Accuracy: 2% of reading (±1 mA) |
| DISPLAY |
Back-lit LCD (128 x 64 pixels), viewable in direct sunlight and low light levels |
| COMPUTER INTERFACE |
RS-232C |
| PC SOFTWARE |
Windows XP/Vista/7 Transformer Analysis Software (included with purchase) |
| INTERNAL TEST RECORD STORAGE |
128 records of 33 readings |
| EXTERNAL TEST RECORD STORAGE |
Up to 999 test records on external USB Flash drive. |
| SAFETY |
|
| ENVIRONMENT |
Operating: -10oC to 50oC (15oF to +122oF)
Storage: (-30oC to 70oC (-22oF to +158oF) |
| HUMIDITY (MAX) |
90% RH @ 40 C (104 F) non-condensing |
| ALTITUDE (MAX) |
2000m (6562 ft) to full safety specifications |
| CABLES |
One 15 ft. (4.6m) Single phase cable, one power cord, one cable bag |
| OPTIONS |
Transportation Case (Can hold unit and cables) |
| WARRANTY |
One year on parts and labor |
| Specifications are valid at nominal voltage and ambient temperature of +25C (+77F). |